Model NO.
CS6530
Portable
Portable
Appliance
Food Analysis, Medical Research, Biochemistry
Certification
CE
Range
0 - 20.00 Mg/L
Temperature Range
0 - 70 C
Optimum Flow Rate
25-100 L/H
IP Rated
IP68
Transport Package
250*160*40
Specification
L*W*H 210*100*65mm
Trademark
CLEAN
Origin
China
HS Code
3122443543
Production Capacity
100000

Product Description

Advanced Calibration Dissolved Ozone Sensor for Reliable Measurements
CS6520 Process Dissolved Ozone Sensor
Advanced Calibration Dissolved Ozone Sensor for Reliable Measurements
stainless steel body
Range: 0 to 2.000 mg/L
0 to 20.00 mg/L
Work Temp: 0 - 50C
Translation: 2A/ppm
Length: 120mm Φ13mm
Cable: 3m
Connector:Terminals
 
CS6530 Dissolved Ozone Sensor
Advanced Calibration Dissolved Ozone Sensor for Reliable Measurements
Principle:Potentiostatic
Range:0 - 2.000 mg/L, 0 - 20.00 mg/L
Resolution:0.001 mg/L, 0.01 mg/L
Temperature range:0 - 70 C
Pressure:0 -6 bar
Optimum Flow Rate:25-100 L/h
Shell material:Glass+PP
Thread Cap:PG13.5
Electrode dimensions:12x120mm
Cable length:5m
Connector:Terminals
IP rated:IP68
CS6730 Dissolved Ozone Sensor
Advanced Calibration Dissolved Ozone Sensor for Reliable Measurements
Principle:Potentiostatic
Range:0 - 2.000 mg/L, 0 - 20.00 mg/L
Resolution:0.001 mg/L, 0.01 mg/L
Temperature range:0 - 70ºC
Pressure:0 -6 bar
Optimum Flow Rate:25-100 L/h
Shell material:Glass+PP
Thread Cap:3/4″ NPT
Electrode dimensions:30x160mm
Cable length:5m
Connector:Terminals
IP rated:IP68
Advanced Calibration Dissolved Ozone Sensor for Reliable Measurements
Product Focus: Dissolved Ozone Controller / Transmitter
Perfectly crafted for accurate online measurement and control, our product excels in water disinfection applications across diverse fields such as the tap water industry, swimming pools, and water parks. It is also ideal for ozone generators and container disinfection in the food and beverage sector. Please note, our sensor is not designed for use with ozone disinfection systems that employ electrolytic water generation.

Featuring a 128 x 64 dot-matrix LCD display, this sensor provides the option to switch between Chinese and English interfaces. With an IP65 protection level, it ensures reliable, all-weather performance.
Our intuitive menu design ensures a user-friendly experience with simple and convenient operation. The graphical prompts offer a beautiful and clear interface for seamless navigation.
With adjustable software digital filtering and enhanced hardware resistance, our sensor promises stable measurements, even in complex industrial environments, providing unmatched reliability.
Designed for global use, our product supports a wide power supply range from 85 to 260 VAC, and we also offer a customized DC model operating from 18 to 36 V DC.
Equipped with an RS-485 digital interface and utilizing the MODBUS-RTU communication protocol, our instrument supports read and write two-way communication, enabling comprehensive remote control capabilities.
ozone measuring range 0.00~20mg/L.00
resolution ratio 0.01 mg/L
Measurement accuracy (electronic unit) ±0.10 mg/L
  temperature measuring range -10.0~130.0ºC
resolution ratio 0.1ºC
Measurement accuracy (electronic unit) ±0.3ºC
Temperature input PT1000
temperature compensation Automatic / manual
Transfer current Output, type Two roads of 4~20 mA (the corresponding range can be set)
Current accuracy ±1% F .S
output loading less-than 500Ω
control Functional relay One (which can be set to the cleaning or alarm function)
Switch amount relay 2 SPST relays
load capacity 2.5A 230VAC
data transmission interface All-way RS485 isolation voltage is 2500Vrms
protocol MODBUS-RTU (read-write two-way communication)
Other parameters working power supply 85~260VAC or 18~36VDC (optional before order)
working temperature 0~60ºC
Operating humidity Relative humidity was <90%
levels of protection IP65
way to install Disk installation
outline dimension (H×W×D) 108×108×132 mm
Open hole size 92.5 * 92.5 mm (positive tolerance)
Advanced Calibration Dissolved Ozone Sensor for Reliable MeasurementsAdvanced Calibration Dissolved Ozone Sensor for Reliable MeasurementsAdvanced Calibration Dissolved Ozone Sensor for Reliable Measurements

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier