• Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming
  • Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming
  • Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming
  • Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming
  • Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming
  • Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming

Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming

After-sales Service: Except for Consumable Electrodes, The Body Is Guar
Warranty: 2 Years
Display: LED
Appliance: Food Analysis, Medical Research, Biochemistry
Portable: Portable
Certification: CE
Gold Member Since 2023

Suppliers with verified business licenses

Shanghai, China
  • Overview
  • Specifications
  • Applications
  • Features
Overview

Basic Info.

Model NO.
DOZ30
Type
Portable Dissolved Ozone Meter
Range
0 -10.00 Mg/L
Resolution
0.01 Mg/L
Accuracy
±2% F.S.
Calibration Point
2 Points
Power
1X1.5V AAA Battery
Transport Package
L*W*H 210*100*65mm
Specification
(H× W× D) 185× 40× 48 mm
Trademark
CLEAN
Origin
China
HS Code
3122443543
Production Capacity
100000

Product Description

CLEAN DOZ30 Dissolved Ozone Tester
Revolutionary way to instantly get dissolved ozone value by using tri-electroded method measuring: faster and accurate, matching up to DPD results, without any reagent consuming. DOZ30 in your pocket is a smart partner to measure dissolved ozone with you.
 

Specifications

Use tri-electroded method measuring: faster and accurate, matching up to DPD results.
2 points calibrate.
Large LCD with backlight.
1*1.5 AAA long battery life.
Self-Diagnostic for easy troubleshooting (e.g battery indicator, message codes).
Auto Lock Function
Floats on water

Applications

Waterworks Drinking water Swimming pool Hospital Sewage

Features

Range 0 -10.00 mg/L
  Resolution 0.01 mg/L
  Accuracy ±2% F.S.
  Temp. Range 0 - 100.0 °C / 32 - 212 °F
  Working Temperature 0 - 60.0 °C / 32 - 140 °F
  Calibration Point 2 points
  LCD 20* 30 mm multi-line crystal display
  Lock Auto / Manual
  Electrode CS6930
  Auto backlight off 1 minute
  Auto power off 5 minutes without key be pressed
  Power 1x1.5V AAA battery
  Dimensions (H×W×D) 185×40×48 mm
  Weight 95g
  Protection IP67

Electrode use and maintenance
[precautions]
1. Keep the platinum ring clean.2. After the electrode is used, please clean theelectrode head with clean water and cover theprotective bottle.
3 If dirt and mineral components are attachedto the electrode diaphragm, the sensitivity willbe reduced, and it may not be possible toperform sufficient measurement. Please ensurethat the platinum ring is clean.4. Service life of electrode. it will varydepending on the frequency of use. Generally.please replace the electrode within one year.
[electrode metal ring cleaning]
The platinum sensing ring of a good Dissolved Ozone Meter electrode should always be kept cleanand bright. If the platinum ring of the electrodebecomes rough or covered by pollutants aftermeasurement, please clean it according to thefollowing methods:Inorganic pollution: immerse the electrode in0.1M dilute hydrochloric acid for 15 minutes,gently wipe the platinum ring of the Dissolved Ozone Meter with a cotton swab, andthen clean it with tap water.
Organic or oil pollution: immerse the electrodein tap water with a small amount of detergent(e.g. detergent) and thoroughly clean thesensing surface of the electrode sensor, Gentlywipe the platinum ring of the electrode with acotton swab, and then rinse it with tap water.if the platinum ring of the electrode has formedan oxide film, please polish the sensing surfacemoderately with toothpaste or 1000 mesh finesandpaper, and then clean it with tap water. (asshown in the right figure)The platinum ring is connected with the glass.Please handle it carefully when polishing

Clean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent ConsumingClean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent ConsumingClean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent ConsumingClean Doz30 Dissolved Ozone Tester Faster and Accurate, Matching up to Dpd Results, Without Any Reagent Consuming

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Trading Company
Business Range
Instruments & Meters
Main Products
Digital RS485 Residual Chlorine Sensor