Display: | Digital |
---|---|
Portable: | Portable |
Appliance: | Food Analysis, Medical Research, Biochemistry |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
![]() PH/ORP/Conductivity/Dissolved Oxygen/Ionic Electrode No Temperature Analog Signal Optional S7,M12 Quick Connector, Digital Electrode Optional M12 Quick Connector ![]() |
|
![]() |
|
CS1751 pH sensor Economical -- for Chemical Process
DownloadCollocations:PH3500PH5500
|
PP body NPT 3/4" thread Range:0-14 Temp: 0-80ºC Temperature sensor: Pt1000/ Pt100/TH10K/NTC22K, Optional Ag/Agcl KCL Ref,Double junction. Sensitive film part no.: B11 Pressure: 0-6 bar Length: 160mm Φ30mm 5m connecting cable with BNC. |
CS1540 pH combination sensor for tough environment use
DownloadCollocations:PH3500PH5500
|
316L Stainless steel body PG13.5 thread Range: 0 -14 pH Temp: 0 - 80ºC SNEX, solid-state, non-exchange reference electrode system, Double junction. Pt1000, Pt100,TH10K temperature sensor optional. Pressure: 0 - 10 bar Length: 120mm Φ13mm 5m connecting cable with BNC |
CS1528 HF pH sensor for HF containing media
DownloadCollocations:PH3500PH5500
|
Glass body PG13.5 thread pH Range: 0 -12 pH Temp. Range: 0 - 90ºC Porous Ceramic pore liquid junction SNEX internal Ref. system (White). Double junction Sensitive film part no.: W28 Temp. sensor: Pt1000/Pt100 optional Pressure: 0 -6 bar Length: 120mm Φ12mm 5m connecting cable with BNC |
CS1529 pH sensor for Seawater for Seawater & Seawater related Download Collocations: PH3500PH5500 |
Glass body PG13.5 thread pH Range: 0 -14 pH Temp. Range: 0 - 90ºC Porous Ceramic pore liquid junction SNEX internal Ref. system (Blue). Double junction. Sensitive film part no.: W02 Temp. sensor: Pt1000/Pt100 optional Pressure: 0 -6 bar Length: 120mm Φ12mm 5m connecting cable with BNC |
CS1597 Non- aqueous media(organic phase) pH sensor
DownloadCollocations:PH3500PH5500
|
Glass body PG13.5 thread pH Range: 0 -12 pH Temp. Range:0 -90ºC Porous Ceramic pore liquid junction SNEX internal Ref. system(Yellow). Double junction Liquid junction: LiCl solution Sensitive film part no.: W28 Pressure: 0 -3 bar Length: 120mm Φ12mm 5m connecting cable with BNC |
CS1543 pH combination sensor for Chemical Process
DownloadCollocations:PH3500PH5500
|
Glass body
PG13.5 thread Range: 0 -14 pH Temp: 0 - 90ºC Porous Ceramic pore liquid junction Ag/AgCl Ref with Ag+ ion trap (or SNEX anti-poison internal system). Double junction. Sensitive film part no.: W02 Temp. sensor:Pt1000 or Pt100(optional) Pressure: 0 -6 bar Length: 120mm Φ12mm 5m connecting cable with BNC |
CS1546 pH combination sensorHigh temperature water environment High temperature resistant reference gel 3.3M KCl gel Non-fillable Low resistance bulb, so less interference, Annular ceramic hole, The contact area is relatively large, It is not easy to block the ceramic hole, It can withstand high pollution. Special blue glass head design, It can effectively prevent Ag/AgCl in the glass detection system Ag/AgCl polarization due to ultraviolet radiation, Increase electrode service life. |
pH range:0~14 zero point (pH):7.00 ± 0.25 temperature range:0 ~ 110 °C Pressure:0 -6 bar temperature probe:Pt1000/NTC10K, optional shaft material:Glass membrane glass:Special blue glass head design can resist ultraviolet interference membrane resistance<350 MΩ low resistance bulb, less interference reference system:Ag/AgCl reference diaphragm:Annular ceramic hole bridge electrolyte:High temperature resistant reference gel 3.3M KCl gel junction:have electrode head:PG13.5 cable length:Coaxial cable 5m connector BNC |
CS1548 pH combination sensor Applicable occasions: various industrial wastewatertap water,RO system (PCB, electroplating, highpollution process)Applicable to environment Low resistance bulb, so less interference Annular ceramic hole, The contact area is relatively large, It is not easy to block the ceramic hole, It can withstand high pollution.
DownloadCollocations:PH3500PH5500
|
pH range:0 - 12 zero point (pH):7.00 ± 0.25 temperature range:0 ~ 90 °C Pressure:0 -6 bar temperature probe:Pt1000/NTC10K, optional shaft material:Glass membrane glass:Special blue glass head design can resist ultraviolet interference membrane resistance:<350 MΩ low resistance bulb, less interference reference system:Ag/AgCl reference diaphragm:Annular ceramic hole bridge electrolyte:3.3M KCl gel junction:have electrode head:PG13.5 cable length:Coaxial cable 5m connector BNC |
CS1549 pH combination sensor High Temperature
DownloadCollocations:PH3500PH5500
|
Glass body PG13.5 thread Range: 0-14pH Temp: 0-90ºC Porous Ceramic pore liquid junction Ag/AgCl Ref with Ag+ ion trap (or SNEX anti-poison internal system). Double junction. Sensitive film part no.: Y01 With Ref electrolyte supplementary port. Temperature sensor: Pt1000 or Pt100(optional) Pressure: 0-6bar Dimension: Φ12mm 5m connecting cable with BNC. |
CS1668 SNEX Combination pH sensor for Sludge, Viscous Fluids, Protein, sulfide media
DownloadCollocations:PH3500PH5500
|
PA+GF body
Range:0-14 Temp: 0-90ºC Temperature sensor: Pt1000 Liquid Junction: SNEX SNEX Ag/AgCL/KCL Ref.sensor system Sensitive film part no.: B11 PG13.5 thread. Pressure: 0-20 bar(@50ºC) Length: 120mm Φ12.7mm 5m connecting cable with BNC. |
CS1568 SNEX Combination pH sensor for Sludge, Viscous Fluids, Protein media, Paint, Sugar Process
DownloadCollocations:PH3500PH5500
|
PP body
Range:0-14 Temp:0-90ºC Temperature sensor: Pt1000 Liquid Junction: SNEX SNEX Ag/AgCL/KCL Ref.sensor system Sensitive film part no.: B11 PG13.5 thread Pressure: 0-10 bar(@50ºC) Length: 120mm Φ12 mm 5m connecting cable with BNC. |
CS1768 SNEX Combination pH sensor for high pressure pipeline: Positive pressure < +20 bar Negative pressure > -10 bar
DownloadCollocations:PH3500PH5500
|
PP body
Range: 0-14 Temp:0-90ºC Temperature sensor: Pt1000/ Pt100/NTC10K, Optional Liquid Junction: SNEX SNEX Ag/AgCl/KCl solid-state, non-exchange reference electrode system NPT 3/4" thread Pressure: +20 ~ -10 bar(@50ºC) 5m connecting cable with BNC. |
CS1778 SNEX Combination pH sensor for flue gas desulfurization process
DownloadCollocations:PH3500PH5500
|
PP body Range: 0-14 Temp:0-90ºC Temperature sensor: Pt1000/ Pt100/NTC10K, Optional Liquid Junction: SNEX SNEX Ag/AgCl/KCl solid-state, non-exchange reference electrode system Sensitive film part no.: W28 NPT 3/4" thread Pressure: 0-20 bar (@50ºC) 5m connecting cable with BNC. |
CS1788 SNEX Combination pH sensor For pure Water/ Low ion concentration water
DownloadCollocations:PH3500PH5500
|
PP body Range: 0-14 Temp:0-90ºC Temperature sensor: Pt1000/ Pt100/NTC10K, Optional Liquid Junction: SNEX SNEX Ag/AgCl/KCl solid-state, non-exchange reference electrode system Sensitive film part no.: W02 NPT 3/4" thread Pressure: 0-20 bar (@50ºC) 5m connecting cable with BNC. |
CS1628 HF pH sensor for HF containing HF concentration<1000ppm
DownloadCollocations:PH3500PH5500
|
PA+GF body Range: 0-12pH Temp:0-80ºC Temperature sensor: Pt1000 Liquid Junction: SNEX SNEX solid-state, non-exchange reference electrode system, Double junction Sensitive film part no.: W28 PG13.5 thread 5m connecting cable with BNC |
CS1637 pH antimony sensor for HF containing HF concentration>1000ppm
DownloadCollocations:PH3500PH5500
|
PA+GF body Range: 2-9pH Temp:0-80ºC Temperature sensor: Pt1000 Liquid junction: SNEX SNEX solid-state, non-exchange reference electrode system, Double junction Sensitive film part no.: antimony PG13.5 thread Pressure: 0-10 bar (@50ºC) 5m connecting cable with BNC |
CS1728 resistant to HF pH sensor for HF containing HF concentration<1000ppm
DownloadCollocations:PH3500PH5500
|
PP body
Range: 0-12pH Temp:0-80ºC Temperature sensor: Pt1000 Liquid Junction: SNEX SNEX solid-state, non-exchange reference electrode system, Double junction Sensitive film part no.: W28 NPT 3/4" thread Pressure: 0-10 bar (@50ºC) 5m connecting cable with BNC. |
CS1737 pH antimony sensor for HF containing HF concentration>1000ppm
DownloadCollocations:PH3500PH5500
|
PP body
Range: 2-9pH Temp:0-80ºC Temperature sensor: Pt1000 Liquid Junction: SNEX SNEX solid-state, non-exchange reference electrode system, Double junction Sensitive film part no.: antimony NPT 3/4" thread Pressure: 0-10 bar (@50ºC) 5m connecting cable with BNC. |
CS1733 pH sensor General purpose
DownloadCollocations:PH3500PH5500
|
PP body
NPT 3/4" thread Range:0-14 Temp: 0-80ºC Ag/Agcl KCL Ref with Ag+ ion trap( or SNEX anti-poison internal system). Double junction. Sensitive film part no.: B11 Pressure: 0-6 bar Length: 160mm Φ30mm 5m connecting cable with BNC. |
CS1753 pH sensor for Chemical Process
DownloadCollocations:PH3500PH5500
|
PP body NPT 3/4" thread Range:0-14 Temp: 0-80ºC Temperature sensor: Pt1000/ Pt100/TH10K, Optional Ag/Agcl KCL Ref with Ag+ ion trap (or SNEX anti-poison internal system). Double junction. Sensitive film part no.: B11 Pressure: 0-6 bar Length: 160mm Φ30mm 5m connecting cable with BNC. |